A/B/C Head Pressure, A/B/C Head Will Not Raise/Lower

Checking the head pressure

Every CarveWright machine should have its headpressure checked regularly. Especially after any shipping. With an inexpensive bathroom scale, this important maintenance step can be performed in minutes. Head Pressure: Sand Paper – 75 to 85 lbs Heavy Duty – 80 to 90 lbs (Needs to be high end for rotary jig.) The weather can affect

A/B/C Trouble Turning On Your Machine

No Power to the Machine

Description of Issue The machine appears to have no power because nothing is displayed on the LCD screen when the machine is turned on. Possible Causes Machine not plugged in, no power to the outlet, machine not turned on, contrast knob for the LCD turned too far down, faulty LCD display, faulty power supply, faulty

A/B/C Trouble Turning On Your Machine

Machine Reboots at Random Times

Description of Issue The machine loses power at random times and reboots to the main menu. Possible Causes Causes include: other machines are on the same power circuit (including unexpected items like AC units, compressors, refrigerators, and sump pumps), a faulty power supply, a faulty controller, a faulty power switch, or a short somewhere in